Nominal Battery Voltages
12, 24, 36, 48, or 60 VDC (Single model)
PV Open Circuit Voltage (VOC)
150 VDC absolute maximum coldest conditions / 145 VDC start-up
Power Conversion Efficiency
97.5% @ 80 Amps in at 48 VDC System voltage - Typical
Charging Regulation
Five Stages: Bulk, Absorption, Float, Silent and Equalization
Remote Display and Controller
Optional Mate or Mate2 with RS232 Serial Communications Port
Operating Temperature Range
Minimum -40° to maximum 60° C
Voltage Regulation Set points
10 to 80 VDC user adjustable with password protection
Environmental Rating
Indoor Type 1
Dimensions
40 x 14 x 10 cm